
New
Condition
New, unused. Hand delivery in the Amarante area or shipping via CTT after payment by bank transfer or MB Way (shipping fee +2.50€); cash on delivery (+5€ shipping fee). Wide input voltage (5 ~ 36 V), most devices can be used, very convenient; The interface is clear and simple, powerful, easy to understand, meeting almost all your needs; Emergency stop function ("STOP" switch); With reverse polarity protection, reverse polarity will not burn the product. Enhanced sleep mode: if this mode is enabled and no operation occurs within 5 minutes, the display automatically turns off; any key wakes it up; You can set different OP, CL, LOP parameters, which are independent of each other and saved automatically; After the module is powered off, all parameter settings are retained. Operating modes: P1: Trigger signal, relay stays on for "OP" time, then turns off; during "OP" time as follows: P1.1: Signal triggered again, invalid; P1.2: Signal triggered again, timer resets; P1.3: Trigger signal again, relay turns off, stops timer; P-2: Trigger signal, relay stays off for "CL" time, then on for "OP" time, then relay turns off; P3.1: Trigger signal, relay turns on after "OP" time, turns off after "CL" time, then cycles; if trigger signal ends, relay turns off, stops timer; number of cycles ("LOP") can be set. P3.2: No trigger signal, relay turns on after "OP" time, turns off after "CL" time, continuously cycling; cycle frequency ("LOP") can be set; P-4: Signal holding function. If a synchronized trigger signal is present, the relay remains on; when the signal disappears, after waiting "OP" time, the relay turns off; if another signal occurs during timing, timing is canceled; Parameters: 1: Operating voltage: DC 5-30 V. 2: Trigger Source: Active-high (3.0 V-24 V), with optocoupler isolation, improves system anti-jamming capability (customers can also short common ground). 3: Output capacity: DC 5 V-36 V, normal temperature, 15A continuous current, power up to 400 W! With improved heat dissipation, maximum current up to 30A. 4: Standby current: 20mA, Operating current: 50mA 5: Lifespan: Unlimited switching operations 6: Operating temperature: -40-85 °C 7: With optocoupler isolation, enhanced anti-jamming capability, industrial-grade board. Attention: The module has active output, output voltage equals input voltage. 2. 'DC + load + ««e»' indicates an internal short between poles, but DC-'e' and load-' poles must not be shorted during use, otherwise the load cannot be controlled on/off, equivalent to the load being constantly powered. Timing range: 0.1 seconds (min) to 999 minutes (max), continuously adjustable. How to select timing range? After setting parameter, press "STOP" button briefly to select timing range on screen; XXX. decimal point at unit place: timing range 1 second to 999 seconds. X decimal point at ten's place: timing range 0.1 seconds to 99.9 seconds. X.X decimal fully lit: timing range 1 minute to 999 minutes. For example, to set "OP" to 3.2 seconds, move decimal point to ten's place, digital display shows 03.2. Parameter description: "OP"-on time, "CL"-off time, "LOP"-number of cycles (1-999 times, "---" represents infinite loop). These parameters are independent of each other but shared across all modes. For example, in P1.1 mode, if "OP" is set to 5 seconds, switching to P1.2 mode keeps "OP" at 5 seconds. On main interface (display 000), briefly press "SET" button to view "OP" ("CL", "LOP") and corresponding time XXX; Some modes only have "OP" parameter (such as P1.1, P1.2, P1.3), brief press of "SET" only shows "OP" and its time; Some models have "OP", "CL", "LOP" parameters (such as P3.1, P3.2), brief press of "SET" button displays "OP" and time, "CL" and time, "LOP" and corresponding count; On main interface, brief press "SET" to view current mode's parameter info, very convenient! How to set parameters? First, read instructions to determine required operating mode. Module powered on, displays current working mode (default P1.1), enters main interface; press "SET" button for 2 seconds then release to enter mode selection interface; briefly press "UP", "DOWN" buttons to select mode (P1.1 ~ P-4). After selecting mode (e.g., P3.2), press "SET" button, then the parameter to set blinks ("OP" on-time, "CL" off-time, "LOP" cycles ("---" means infinite loop)); use "UP", "DOWN" keys to adjust parameter value, supports long press (fast increase/decrease) and light press (increment/decrement by one unit); then briefly press "STOP" button to select decimal point position, choose timing range (0.1 seconds to 999 minutes); briefly press "SET" button to set next parameter of current mode, procedure same as above. After parameters set, press and hold "SET" button for 2 seconds and release, current mode name flashes once, then returns to main screen, parameters successfully set! Main interface: relay working status not displayed as "000" (no decimal point), with decimal point indicating relay status. Mode selection screen: press and hold "SET" button to enter; after configuration, long press "SET" to exit back to main screen. "STOP" button extended function: Relay enable mode: NO: Relay allowed to operate during "OP" on-time; OFF: Relay conduction prohibited, always closed. On main interface, briefly press "STOP" button to toggle between ON and OFF, current state flashes, then returns to main screen. (This feature is emergency stop function, click to turn off relay) Sleep mode: "C-P" Sleep mode: after 5 minutes without any operation, digital display turns off automatically, program runs normally; "O-d" Normal mode: digital display always on; Press "STOP" button for two seconds and release to switch between "C-P" and "O-d" states, current state flashes then returns to main screen. Package Includes: 1 x Cycle Trigger Timer Switch 5-30V MOS Tube Circuit Control Board Module
